DIGIT SELECT KEY
VALUE SELECT KEY
MENU KEY
dSPYno
Item to be displayed at power
on.
PULSES
Number of pulses per zero
(Quadrature only)
GAtE t
Gate time
(If not Batch)
dSPY t
Relay output time
( Batch only )
ti Out
Time out to display "0" if no
input (If not Batch)
bAtCH
Batch (batch mode only)
FiLtEr
Filtering
1
Enter display item #
00000 00000 00000
00000 00000
Enter number of pulses
199.99
Select value from .01 to
199.99 seconds
199.99
Select value from .01 to
199.99 seconds
199.99
Select value from .01 to
199.99 seconds
00000
Batch total and grand totals
stop at preset values or
count all input pulses
00000
Reset and count direction
00000
Reset at end of gatetime or
with external signal
0000
Grand total or batch #
0000
Batch start
00000
Filter type
00000
Display value
1 Display item 1
2 Display item 2
3 Display item 3
Select 0 through 9 for
flashing digit.
Select 0 through 9 for
flashing digit.
Select 0 through 9 for
flashing digit.
Select 0 through 9 for
flashing digit.
0 Batch preset, grand preset
1 Batch all, grand preset
2 Batch preset, grand all
3 Batch all, grand all
0 Reset to 0 and count up
1 Set to offset1 & cnt down
0 Use gatetime to reset
1 Use External Function
reset
0 Item #2 = grand total
1 Item #2 =total # of batches
0 Display "rEAdy" after reset
1 Start batch after reset
0 Adaptive filter
1 Conventional filter
0 Unfiltered display value
1 Filtered display value